Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Korean Journal of Dental Materials ; (4): 59-68, 2023.
Article in English | WPRIM | ID: wpr-1002141

ABSTRACT

This study compared the effectiveness of self-propelling diatom microbubblers to clean dental appliances with commercial denture cleaning agents according to the Ministry of Food and Drug Safety’s guidelines. The microbubbler is made by doping diatoms with MnO2 nanosheets that can decompose hydrogen peroxide to generate oxygen bubbles. Artificial saliva is prepared in accordance with the criteria presented by the American Dental Association, dispensed, and dried in 96 well plates. Experimental groups include 10-15% NaOCl (positive control), distilled water (negative control), diatom microbubbler A (Aulacoseira, MnO2-polydopamine (PDA)-A), diatom microbubbler M (Melosira nummuloids, MnO2-sugar (S)-M), Polident (GlaxoSmithKline, Dungarvan, Ireland), Dentfix-forte (Helago-Phama GmbH&Co, Parchim, Germany). After washing, absorbance (OD 600) was measured. If the absorbance was 70% or higher, the condition was determined to have “cleaning power potency,”Statistical significance was evaluated by one-way ANOVA and Bonferroni correction to compare cleaning effects among groups (p<0.05).The average cleaning rates were 93.8±1.0% in NaOCl (positive control) and 79.1±1.5% in distilled water (negative control).With the diatom microbubbler A, the average cleaning rate was 79.8±4.5% in the 3% H 2O 2 2 mg/mL, 64.7±5.5% in 6% H 2O 2 2 mg/mL, and 81.9±7.9% in 6% H 2O 2 4 mg/mL. The diatom microbubbler M group showed average cleaning rates of 88.5±3.6% in 3% H2O2 2 mg/mL, 75.8±4.0% in 6% H2O2 2 mg/mL, and 84.5±4.5% in 6% H2O2 4 mg/mL. Finally, conventional denture cleaning agents showed average cleaning rates of 88.2±1.2% in Polident and 83.3±3.0% in Dentfix-forte. The positive control group had significant differences from all experimental groups, but the negative control group showed significant differences only in A2 and A3, M1 and M2, M3, Polident, and Dentfix-forte (F=190.141, p<0.001). Among all groups except the positive control group, MnO2 -S-M mixed with 3% H2O2 2 mg/mL showed the highest cleaning rate. As the results of this study show, diatom complexes exhibit cleaning effects compatible with conventional denture cleaning agents. Further studies need to be conducted to narrow down the specific optimal conditions of diatom microbubblers and maximize the cleaning effect.

SELECTION OF CITATIONS
SEARCH DETAIL